Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
BMC Cardiovasc Disord ; 23(1): 222, 2023 04 29.
Artigo em Inglês | MEDLINE | ID: mdl-37120542

RESUMO

BACKGROUND: Preterm birth and low birthweight have been associated with increased risk of heart failure and cardiovascular disease in young adulthood. However, results from clinical studies of myocardial function are not consistent. Echocardiographic strain analyses allow detection of early stages of cardiac dysfunction, and non-invasive estimates of myocardial work can provide additional information on cardiac function. We aimed to evaluate left ventricular (LV) myocardial function including measures of myocardial work in young adults born very preterm (gestational age < 29 weeks) or with extremely low birthweight (< 1000 g) (PB/ELBW), compared with term-born age- and sex matched controls. METHODS: 63 PB/ELBW and 64 controls born in Norway in the periods 1982-1985, 1991-1992, and 1999-2000 were examined with echocardiography. LV ejection fraction (EF) and LV global longitudinal strain (GLS) were measured. Myocardial work was estimated from LV pressure-strain loops after determination of GLS and construction of a LV pressure curve. Diastolic function was evaluated by determination of the presence or absence of elevated LV filling pressure, including measures of left atrial longitudinal strain. RESULTS: The PB/ELBW with mean birthweight 945 (standard deviation (SD) 217) grams, mean gestational age 27 (SD 2) weeks, and mean age 27 (SD 6) years had LV systolic function mainly within normal range. Only 6% had EF < 50% or impaired GLS >-16%, but 22% had borderline impaired GLS between - 16% and - 18%. Mean GLS in PB/ELBW (-19.4% (95% confidence interval (CI) -20.0, -18.9)) was impaired compared to controls (-20.6% (95% CI -21.1, -20.1)), p = 0.003. Lower birthweight was associated to more impaired GLS (Pearson correlation coefficient - 0.2). Means of EF, measures of diastolic function including left atrial reservoir strain, global constructive and wasted work, global work index and global work efficiency was similar in PB/ELBW and controls. CONCLUSION: The young adults born very preterm or with extremely low birthweight had impaired LV-GLS compared to controls, although systolic function mainly within normal range. Lower birthweight was associated with more impaired LV-GLS. These findings could indicate an elevated lifetime risk of developing heart failure in preterm born individuals. Measures of diastolic function and myocardial work were similar compared to controls.


Assuntos
Fibrilação Atrial , Insuficiência Cardíaca , Nascimento Prematuro , Disfunção Ventricular Esquerda , Recém-Nascido , Feminino , Humanos , Adulto Jovem , Adulto , Lactente , Estudos de Coortes , Recém-Nascido de Peso Extremamente Baixo ao Nascer , Lactente Extremamente Prematuro , Peso ao Nascer , Função Ventricular Esquerda , Volume Sistólico , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/epidemiologia
2.
Int J Cardiovasc Imaging ; 37(7): 2111-2123, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33710496

RESUMO

The aims of this study was to assess the effect of using a four chamber versus a three plane model on speckle tracking derived global longitudinal strain, the effects of drift compensation, the effect of assessing strain in different layers and finally the interplay between these aspects for the assessment of strain in neonates. Speckle tracking derived longitudinal strain was obtained from 22 healthy neonates. ANOVA, Bland-Altman analyses, coefficients of variation and assessment of intraclass correlation coefficients were conducted to assess the effect of the abovementioned aspects as well as assess both inter-observer and intra-observer variability. Neither the use of the three plane model versus the four chamber model nor the use of drift compensation had a substantial effect on global longitudinal strain (less than 1%, depending on which layer was being assessed). A gradient was seen with increasing strain from the epicardial to endocardial layers, similar to what is seen in older subjects. Finally, drift compensation introduced more discrepancy in segmental strain values compared to global longitudinal strain. Global longitudinal strain in healthy neonates remains reasonably consistent regardless of whether the three plane or four chamber model is used and whether drift compensation is applied. Its value increases when one moves from the endocardial to the epicardial layer. Finally, drift compensation introduces more discrepancy for regional measures of longitudinal strain compared to global longitudinal strain.


Assuntos
Ecocardiografia , Endocárdio , Idoso , Endocárdio/diagnóstico por imagem , Humanos , Recém-Nascido , Variações Dependentes do Observador , Valor Preditivo dos Testes , Reprodutibilidade dos Testes
3.
Pediatr Cardiol ; 42(4): 743-752, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33492429

RESUMO

Clinical application of strain in neonates requires an understanding of which image acquisition and processing parameters affect strain values. Previous studies have examined frame rate, transmitting frequency, and vendor heterogeneity. However, there is a lack of human studies on how user-regulated spatial and temporal smoothing affect strain values in 36 neonates. This study examined nine different combinations of spatial and temporal smoothing on peak systolic left ventricular longitudinal strain in 36 healthy neonates. Strain values were acquired from four-chamber echocardiographic images in the software-defined epicardial, midwall, and endocardial layers in the six standard segments and average four-chamber stain. Strain values were compared using repeated measure ANOVAs. Overall, spatial smoothing had a larger impact than temporal smoothing, and segmental strain values were more sensitive to smoothing settings than average four-chamber strain. Apicoseptal strain decreased by approximately 4% with increasing spatial smoothing, corresponding to a 13-19% proportional change (depending on wall layer). Therefore, we recommend clinicians be mindful of smoothing settings when assessing segmental strain values.


Assuntos
Ecocardiografia/métodos , Ventrículos do Coração/diagnóstico por imagem , Disfunção Ventricular Esquerda/diagnóstico por imagem , Endocárdio/diagnóstico por imagem , Feminino , Ventrículos do Coração/fisiopatologia , Humanos , Recém-Nascido , Masculino , Reprodutibilidade dos Testes , Software , Sístole , Disfunção Ventricular Esquerda/fisiopatologia , Função Ventricular Esquerda
4.
Pediatr Cardiol ; 41(1): 1-11, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31673733

RESUMO

Reference values for left ventricular systolic strain in healthy neonates are necessary for clinical application of strain. The objectives of this systematic review were to identify echocardiographic studies that presented left ventricular strain values in healthy neonates, perform a meta-analysis for speckle tracking-derived global longitudinal strain, and identify areas that require further investigation. A structured search was applied to MEDLINE, Embase, and Cochrane Central Register of Clinical Trials in search of echocardiographic studies that presented left ventricular strain in healthy neonates. 244 studies were identified, of which 16 studies including speckle tracking and tissue Doppler strain in the longitudinal, radial, and circumferential directions passed the screening process. Out of these 16 studies, a meta-analysis was performed on the 10 studies that reported speckle tracking global longitudinal strain. Mean speckle tracking-derived global longitudinal strain was 21.0% (95% Confidence Interval 19.6-22.5%, strain given as positive values). When the studies were divided into subgroups, mean speckle tracking global longitudinal strain from the four-chamber view was 19.5% (95% Confidence Interval 18.0-21.0%) and that derived from all three apical views was 22.5% (95% CI 20.6-24.7%), indicating that global longitudinal strain from the four-chamber view is slightly lower than global longitudinal strain from all three apical views. Neonatal strain values were close to strain values in older subjects found in previous meta-analyses. Further studies are recommended that examine strain rate, segmental strain values, strain derived from short axis views, and strain in the first few hours after birth.


Assuntos
Ventrículos do Coração/diagnóstico por imagem , Função Ventricular Esquerda/fisiologia , Ecocardiografia/normas , Feminino , Humanos , Recém-Nascido , Masculino , Valores de Referência , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...